This is a very good quality print (scan) of the original SONY service manual. The original from Sony is on very thin paper. Nevertheless it is very clear and sharp and excellent readable. I'm very satisfied to have now this rare document. I've looking for it many years (infrequent). It contains very detailed circuit diagrams, exploded views, part lists, PCB view with good readable connection lines. Very recommended.
 ;
A complete manual with all the needed details of calibrations and service instructions about the radio receiver.
A big deal.
Many thanks !
 ;
Fast delivery and good quality copy. To be recommended
 ;
Excellent product, very clear print. Detailed circuit and assembly diagrams - this enabled me to repair my CD player with confidence. I highly recommend this site.
 ;
Fast access, 100% correct and complete service manual
6. Press CH DOWN button on the unit until the CTL waveform has shifted from its original position (not the position achieved in step 5, but the position of CTL waveform in step 4) by approximately -2msec. Make sure that the envelope is simply attenuated (shrinks in height) once CTL waveform passes its original position and is further brought in the minus direction. 7. Set the Tracking Control Circuit to the center position by pressing CH UP button and then â PLAY â button.
Dropping envelope level at the end of track.
Fig. M8 Envelope is adjusted properly. (No envelope drop)
1-C. Checking/Adjustment of Envelope Waveform
Purpose: To achieve a satisfactory picture and precise tracking. Symptom of Misalignment: If the envelope output is poor, noise will appear in the picture. The tracking will then lose precision and the playback picture will be distorted by any slight variation of the Tracking Control Circuit. 1. Connect the oscilloscope to TP008 (C-PB) on the Main CBA. Use TP002 (RF-SW) as a trigger. 2. Playback the Gray Scale on the Alignment Tape (FL6NS8). Set the Tracking Control Circuit to the center position by preessing both CH UP button and CH DOWN button on the unit at the same time. Adjust the height of Guide Rollers [2] and [3] (Fig. M3, Page 2-3-7) watching the oscilloscope display so that the envelope becomes as flat as possible. To do this adjustment, turn the top of the Guide Roller with the Guide Roller Adj. Screwdriver. 3. If the envelope is as shown in Fig. M7, adjust the height of Guide Roller [2] (Refer to Fig. M3) so that the waveform looks like the one shown in Fig. M9. 4. If the envelope is as shown in Fig. M8, adjust the height of Guide Roller [3] (Refer to Fig. M3) so that the waveform looks like the one shown in Fig. M9. 5. When Guide Rollers [2] and [3] (Refer to Fig.M3) are aligned properly, there is no envelope drop either at the beginning or end of track as shown in Fig. M9. Dropping envelope level at the beginning of track.
Fig. M9 Note: Upon completion of the adjustment of Guide Rollers [2] and [3] (Refer to Fig. M3), check the X Value by pushing the CH UP or DOWN buttons alternately, to check the symmetry of the envelope. Check the number of pushes to ensure center position. The number of pushes CH UP button to achieve 1/2 level of envelope should match the number of pushes CH DOWN button from center. If required, redo the âX Value Alignment.â
1-D. Azimuth Alignment of Audio/Control/ Erase Head
Purpose: To correct the Azimuth alignment so that the Audio/ Control/Erase Head meets tape tracks properly. Symptom of Misalignment: If the position of the Audio/Control/Erase Head is not properly aligned, the Audio S/N Ratio or Frequency Response will be poor. 1. Connect the oscilloscope to the audio output jack on the rear side of the deck. 2. Playback the alignment tape (FL6NS8) and confirm that the audio signal output level is 6kHz. 3. Adjust Azimuth Adj. Screw so that the output level on the AC Voltmeter or the waveform on the oscilloscope is at maximum. (Fig. M6)
Fig. M7
2-3-8
T6500MA
|
|
 |
> |
|